ZHANG Yuzhen, JI Xingquan, YU Yongjin, LIANG Yongliang, FAN Shuxian. Insulation condition assessment method of mine-used transformer based on spatio-temporal information fusio[J]. Journal of Mine Automation, 2017, 43(9): 75-82. DOI: 1671-251X(2017)09-0075-08DOI:10.13272/j.issn.1671-251x.2017.09.014
Citation: ZHANG Yuzhen, JI Xingquan, YU Yongjin, LIANG Yongliang, FAN Shuxian. Insulation condition assessment method of mine-used transformer based on spatio-temporal information fusio[J]. Journal of Mine Automation, 2017, 43(9): 75-82. DOI: 1671-251X(2017)09-0075-08DOI:10.13272/j.issn.1671-251x.2017.09.014

Insulation condition assessment method of mine-used transformer based on spatio-temporal information fusio

More Information
  • The existing condition assessment methods of mine-used transformer mostly focus on assessment model and theory research, while neglect temporal and spatial correlation analysis of evaluation indexes. In view of the problem, an insulation condition assessment method of mine-used transformer based on spatio-temporal information fusion was proposed. In view of randomness and fuzziness of data information in the insulation condition assessment method of mine-used transformer, a multilateral condition assessment system of mine-used transformer was established. Variable weight coefficients of factors layer of evaluation model were determined introducing association rules and variable weight synthesizing theory. A fuzzy membership function was formulated to describe the factor layer, and its original basic probability assignment was calculated. The basic probability assignment of factors and cycles in evaluation model was fused based on D-S evidence theory, firstly, basic probability assignment of factors obtained by the assessment factors layer and its weight coefficient were fused based on time domain information fusion, and then the time domain fusion information was used for airspace fusion, finally insulation condition of mine-used transformers was judged combining reliability criterion. The results of practical example prove that the proposed method can evaluate the insulation condition of mine-used transformers accurately and effectively.
  • Related Articles

    [1]YU Liya, ZHAO Yongfang, ZHANG Lingyun, CHEN Guangbo. Coal and gas outburst risk evaluation based on cloud model and D -S theory[J]. Journal of Mine Automation, 2020, 46(11): 106-112. DOI: 10.13272/j.issn.1671 -251x.2020040029
    [2]WANG Meng-dong, CHEN Xiang, GUAN Yu, XIAO Shu-yan. Research of double-threshold spectrum sensing algorithm based on D-S theory[J]. Journal of Mine Automation, 2013, 39(12): 82-85. DOI: 10.7526/j.issn.1671-251X.2013.12.020
    [3]XIAO Shu-yan, CUI Jie. Research of spectrum sensing algorithm of cognitive radio based on improved D-S evidence theory[J]. Journal of Mine Automation, 2013, 39(8): 42-46. DOI: 10.7526/j.issn.1671-251X.2013.08.012
    [4]LI Bo, HUANG Yuan-yue. Underground Risk Assessing Method Based on Rough Set and D-S Evidence Theory[J]. Journal of Mine Automation, 2011, 37(11): 38-40.
    [5]FU Hua, KANG Hai-chao, LIANG Ming-guang. Research of Gas Monitoring System Based on BP Network and D-S Evidence Theory[J]. Journal of Mine Automation, 2011, 37(8): 159-161.
    [6]JIAO Lu-qin, YAO Qi, YANG Li. Fault Diagnosis Method of Rotor Broken Bar of Asynchronous Motor Based on SVM and D-S Evidence Theory[J]. Journal of Mine Automation, 2010, 36(6): 43-48.
    [7]SHI Li-ping, FAN Li-li, BU Ling-chen, ZHANG Jian-wei, WANG Tai-xu. Application of Improved p-q Detection Method in D-STATCOM Current Detectio[J]. Journal of Mine Automation, 2010, 36(3): 53-57.
    [8]WANG Zhen, LI Chang-qing, AN Wei-peng. Research of Mine Monitoring and Control System Based on Hybrid Mode of C/S and B/S[J]. Journal of Mine Automation, 2008, 34(1): 70-72.
    [9]CHEN Ying, NI Jian-jun, XU Li-zhong. The Decision Method of Multi-attribute and Multi-men Based on D-S Evidence Theory and Its Applicatio[J]. Journal of Mine Automation, 2005, 31(5): 16-18.
    [10]HAN Ya. Application of PWC318 in Σ-Δ A/D Convertor[J]. Journal of Mine Automation, 2003, 29(2): 17-19.
  • Cited by

    Periodical cited type(2)

    1. 欧阳勇,万豆,高榕,叶志伟. 基于自注意力的TCN-Transformer的电网单相故障检测方法. 微电子学与计算机. 2022(09): 89-97 .
    2. 黄河,高松,朱磊,姜念,杨昆. 网架结构的配电自动化适应性优化方法研究. 电子设计工程. 2020(11): 84-87 .

    Other cited types(0)

Catalog

    Article Metrics

    Article views (86) PDF downloads (24) Cited by(2)