WANG Tuan-jie, HU Jian-wei. Design of humidity controller of mine-used frequency converter[J]. Journal of Mine Automation, 2013, 39(12): 107-109. DOI: 10.7526/j.issn.1671-251X.2013.12.027
Citation: WANG Tuan-jie, HU Jian-wei. Design of humidity controller of mine-used frequency converter[J]. Journal of Mine Automation, 2013, 39(12): 107-109. DOI: 10.7526/j.issn.1671-251X.2013.12.027

Design of humidity controller of mine-used frequency converter

More Information
  • In view of problem that mine-used frequency converter is easy to be damaged under situation of condensation, a humidity controller of mine-used frequency converter was designed. The humidity controller is composed of main controller, temperature and humidity sensor, condensation sensor and heating device. When inside of the frequency converter has condensation caused by big temperature difference of inside and outside of the frequency converter, the main controller makes the frequency converter to stop working after detecting blocking signal of the condensation sensor, meanwhile the main controller opens heating device to accelerate water evaporation in the frequency converter and sends alarming signal. When the main controller detects internal environment of the frequency converter is recovered, it cancels the alarming signal and makes the frequency converter to recover normal working. Actual test result shows that the humidity controller can ensure mine-used frequency converter work reliably under moist environment.
  • Related Articles

    [1]JIANG Zhihao, YU Qun, DONG Li. Fault diagnosis of circuit breaker based on improved dynamic time warping algorithm[J]. Journal of Mine Automation, 2016, 42(8): 52-55. DOI: 10.13272/j.issn.1671-251x.2016.08.013
    [2]LIU Jingyan, LI Yudong, GUO Shunjing. Gear box fault diagnosis based on Elman neural networ[J]. Journal of Mine Automation, 2016, 42(8): 47-51. DOI: 10.13272/j.issn.1671-251x.2016.08.012
    [3]QIAO Shuyun. Fault diagnosis for mine hoist bearing based on EMD method[J]. Journal of Mine Automation, 2016, 42(4): 51-54. DOI: 10.13272/j.issn.1671-251x.2016.04.012
    [4]PU Yasong, GUO Dewei, ZHANG Wenbi. Application of fault diagnosis technologies in coal mine machinery[J]. Journal of Mine Automation, 2015, 41(4): 36-39. DOI: 10.13272/j.issn.1671-251x.2015.04.010
    [5]LIU Pu, FU Sheng. Design of embedded online monitoring and fault diagnosis system of mine ventilator[J]. Journal of Mine Automation, 2013, 39(12): 103-106. DOI: 10.7526/j.issn.1671-251X.2013.12.026
    [6]WAN Zhi-qiang, SONG Jian-cheng, LEI Zhi-peng, WEN Min-min, LI Chuan-yang. Development of system of on-line monitoring, fault diagnosis and prewarning for insulation of mine-used dry-type transformer[J]. Journal of Mine Automation, 2013, 39(10): 1-5. DOI: 10.7526/j.issn.1671-251X.2013.10.001
    [7]WANG Ai-ming, WU Jing-hong, MENG Guo-ying, PANG Zheng-duo, DUAN Peng-fei. Development of On-line Monitoring System of Fault of Scraper Conveyor’s Chai[J]. Journal of Mine Automation, 2010, 36(5): 91-93.
    [8]WANG Qi-jun~, CHENG Jiu-long~. Research of Fault Diagnosis of Gas Sensor Based on Information Fusion Technology[J]. Journal of Mine Automation, 2008, 34(2): 22-25.
    [9]LI Xiao-qing, ZHANG Wen-xiang. The Expert System of Fault Diagnosis of Hydraulic System[J]. Journal of Mine Automation, 2005, 31(4): 11-13.
    [10]WANG Chang-quan , LING Wei-ye . Research on the Vibration and Temperature Monitoring and Control System in Fault Diagnosis[J]. Journal of Mine Automation, 2002, 28(5): 6-7.

Catalog

    Article Metrics

    Article views (48) PDF downloads (16) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return