WEI Shao-liang, LIU Da-hai, CHANG Ying, ZHOU Guang-ping, WANG Xue-hui. Research of channel transmission attenuation characteristics of underground low-voltage power line[J]. Journal of Mine Automation, 2013, 39(12): 48-50. DOI: 10.7526/j.issn.1671-251X.2013.12.012
Citation: WEI Shao-liang, LIU Da-hai, CHANG Ying, ZHOU Guang-ping, WANG Xue-hui. Research of channel transmission attenuation characteristics of underground low-voltage power line[J]. Journal of Mine Automation, 2013, 39(12): 48-50. DOI: 10.7526/j.issn.1671-251X.2013.12.012

Research of channel transmission attenuation characteristics of underground low-voltage power line

More Information
  • In view of problems that network topology of underground low-voltage power line is complex and multi-path transmission model is difficult to suit channel modeling of underground low-voltage power line, the paper made a test for channel transmission characteristics of underground low-voltage power line. It indicated that attenuation of underground signal increases with increasing of transmission distance and changes with changing of frequency, and has certain selective fading. It took selective fading as resonant frequency point and used model of series resonant circuit to make modeling simulation for channel attenuation characteristics of underground low-voltage power line, and the simulation result shows that the model of series resonant circuit can well reflect channel transmission characteristics of underground low-voltage power line.
  • Related Articles

    [1]ZHANG Zhaoxi, ZHANG Hongle, HUANG Yanfa, CHEN Xingxiang, JIA Haicheng, YUAN Pengsheng. Fault line selection method for resonant grounding systems based on DTW-Hilbert and improved K-means[J]. Journal of Mine Automation, 2024, 50(11): 169-178. DOI: 10.13272/j.issn.1671-251x.2024090076
    [2]GUO Fengyi, RUAN Junyi, DENG Yong, WANG Zhiyong, WANG Shaolei, LI Chuan, WANG Peilong. Development of series fault arc simulation experimental device[J]. Journal of Mine Automation, 2018, 44(7): 66-70. DOI: 10.13272/j.issn.1671-251x.2017120024
    [3]GUO Fengyi, BILGUUN Baatar, REN Xue, FANG Zhipeng, ZHANG Hongbo. Comparative analysis of series fault arc detection methods[J]. Journal of Mine Automation, 2017, 43(8): 31-36. DOI: 10.13272/j.issn.1671-251x.2017.08.007
    [4]YANG Xinwei, LIU Weina, JIANG Bo. New line selection method of resonant grounding system based on energy and correlatio[J]. Journal of Mine Automation, 2016, 42(12): 59-63. DOI: 10.13272/j.issn.1671-251x.2016.12.013
    [5]MA Chunyan, GONG Ying. Fuzzy comprehensive line selection method of resonance grounding fault in coal mine[J]. Journal of Mine Automation, 2015, 41(11): 81-84. DOI: 10.13272/j.issn.1671-251x.2015.11.020
    [6]LIN Yin, DENG Fei, LIU Ya-hui. An improved voltage measuring method for single battery in series batteries[J]. Journal of Mine Automation, 2013, 39(6): 106-108.
    [7]FAN Yi-long~, LI Hang~, YOU Guo-dong~. Design of Selective Leakage Protection Circuit Based on Method of Amplitude Discrimination and Phase Discriminatio[J]. Journal of Mine Automation, 2010, 36(7): 104-106.
    [8]WU Yan-hua, YAN Jiao-sheng, ZHANG Wei. Design of Double-transistor Forward Circuit Based on Series Connection of IGBT[J]. Journal of Mine Automation, 2009, 35(9): 99-101.
    [9]LI Bin, YUAN Zhen-hai. Study of Principle of Selective Leakage Protection of Zero Sequence DC of Low-voltage Power Network Underground and Its Implementatio[J]. Journal of Mine Automation, 2007, 33(1): 57-59.
    [10]CAO Ji-jun, PAN Ting-long. Study on a New Type of Resonant DC Link Converter[J]. Journal of Mine Automation, 2004, 30(6): 12-14.

Catalog

    Article Metrics

    Article views (38) PDF downloads (16) Cited by()
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return