QIU Shiguang, LI Mei. A distinguishing method of open-circuit IGBT of three-level NPC inverter[J]. Journal of Mine Automation, 2014, 40(9): 99-102. DOI: 10.13272/j.issn.1671-251x.2014.09.023
Citation: QIU Shiguang, LI Mei. A distinguishing method of open-circuit IGBT of three-level NPC inverter[J]. Journal of Mine Automation, 2014, 40(9): 99-102. DOI: 10.13272/j.issn.1671-251x.2014.09.023

A distinguishing method of open-circuit IGBT of three-level NPC inverter

More Information
  • For problem of large calculated amount of existing distinguishing method of open-circuit IGBT of three-level NPC inverter, all kinds of open-circuit states of IGBT were simulated, and the causes of bus neutral-point voltage deviation were analyzed, then a simple method to distinguish the open-circuit IGBT was proposed. The method achieves distinguishing of open-circuit IGBT by detecting bus neutral-point voltage and three-phase output voltage of inverter, which needs no extra hardware. The simulation results verify effectiveness of the method.
  • Related Articles

    [1]WANG Yue, SHI Han, RONG Xiang, JIANG Dezhi. Coordinated optimization method for IGBT peak voltage suppression of mine-used inverter[J]. Journal of Mine Automation, 2022, 48(12): 129-136, 143. DOI: 10.13272/j.issn.1671-251x.17884
    [2]LIANG Hong. Open-circuit fault diagnosis method for switching tube of mine NPC three-level inverter[J]. Journal of Mine Automation, 2022, 48(10): 142-150. DOI: 10.13272/j.issn.1671-251x.17974
    [3]REN Xiaohong, WAN Hong, YU Xiao, DING Enjie. Open-circuit fault diagnosis of three-level inverter based on Park transformatio[J]. Journal of Mine Automation, 2020, 46(5): 82-86. DOI: 10.13272/j.issn.1671-251x.17523
    [4]YU Jing, MO Xiuquan, XU Na. Research on predictive control for mine high-pressure three-level ANPC inverter[J]. Journal of Mine Automation, 2016, 42(10): 85-90. DOI: 10.13272/j.issn.1671-251x.2016.10.020
    [5]QIU Shiguang, LI Siguang. A fault-tolerance topology of three-level four-leg NPC inverter[J]. Journal of Mine Automation, 2016, 42(10): 70-73. DOI: 10.13272/j.issn.1671-251x.2016.10.016
    [6]WANG Kezhi, ZHAO Wenhan, WANG Tao, YANG Gang, CHENG Guodong, GENG Yiwen. A strategy of neutral-point potential balance control and common-mode voltage suppressio[J]. Journal of Mine Automation, 2014, 40(9): 90-93. DOI: 10.13272/j.issn.1671-251x.2014.09.021
    [7]ZHAO Xia, FANG En, XIA Chenyang, TU Wei, GUO Quanju. Analysis of loss distribution for power devices of active neutral point clamped three-level inverter[J]. Journal of Mine Automation, 2014, 40(4): 55-59. DOI: 10.13272/j.issn.1671-251x.2014.04.013
    [8]YIN Xiang-qing. A new generation of high-power cascade H-bridge rectifier for voltage balancing control[J]. Journal of Mine Automation, 2013, 39(11): 23-27. DOI: 10.7526/j.issn.1671-251X.2013.11.007
    [9]GUO Yi-dan, SONG Shu-zhong, MA Jian-wei, ZHU Jin-hong. Analysis and Simulation of IGBT Power Consume Based on PSpice[J]. Journal of Mine Automation, 2009, 35(10): 53-56.
    [10]LI Xiao-dong, WANG Jing, ZHANG Yong-jun, LI Jing. Study of Driving and Protection of IGBT for Large Power Inverter of Three Level[J]. Journal of Mine Automation, 2007, 33(3): 64-66.