YANG Ning, ZHANG Lin, XU Chun-yu. Research of dead-time compensation strategy for three-level inverter[J]. Industry and Mine Automation, 2013, 39(5): 55-59.
Citation: YANG Ning, ZHANG Lin, XU Chun-yu. Research of dead-time compensation strategy for three-level inverter[J]. Industry and Mine Automation, 2013, 39(5): 55-59.

Research of dead-time compensation strategy for three-level inverter

  • Publish Date: 2013-05-10
  • The paper analyzed dead-time effect and working principle of diode-clamped three-level inverter, proposed a dead-time compensation method which is suitable for diode-clamped three-level inverter based on double carrier modulation. By adjusting dead-time of trigger pulse on different current flow paths, the method realizes level conversion unaffected by dead-time, which means avoiding or reducing dead-time effect. The simulation result shows that the method reduces the 5th and 7th harmonic contents and total harmonic distortion, increases effective current value and has better compensation effect compared with normal dead-time compensation method.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (22) PDF downloads(2) Cited by()