ZOU Yun-long, DENG Gan-bo, ZHANG Qing-hua, et al. Discussion of layout position of gas emission warning sensor in heading face[J]. Industry and Mine Automation, 2013, 39(4): 44-47.
Citation: ZOU Yun-long, DENG Gan-bo, ZHANG Qing-hua, et al. Discussion of layout position of gas emission warning sensor in heading face[J]. Industry and Mine Automation, 2013, 39(4): 44-47.

Discussion of layout position of gas emission warning sensor in heading face

  • Publish Date: 2013-04-10
  • For situation that existing mine gas sensor is mainly used for monitoring disasters of gas explosion and gas accumulation, and not for monitoring gas emission characteristics of working face, the paper discussed a kind of layout scheme of gas sensor. The test results show that the sensors lay out 5 m distance far from the working face, the monitoring data conform to the real gas emission monitoring of working face, and meet needs of monitoring gas emission characteristics. Current arrangement of gas sensor on head-on of heading face can meet needs of monitoring gas emission characteristics.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (43) PDF downloads(3) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return