WANG Fu-zhong~, JING Peng-hui~, ZHANG Hong-tao~. Research of Out-of-step Prevented Control Strategy of Low-speed Permanent Magnet Linear Synchronous Motor[J]. Industry and Mine Automation, 2009, 35(11): 46-49.
Citation: WANG Fu-zhong~, JING Peng-hui~, ZHANG Hong-tao~. Research of Out-of-step Prevented Control Strategy of Low-speed Permanent Magnet Linear Synchronous Motor[J]. Industry and Mine Automation, 2009, 35(11): 46-49.

Research of Out-of-step Prevented Control Strategy of Low-speed Permanent Magnet Linear Synchronous Motor

  • Publish Date: 2009-11-10
  • In operation process,key of stable operation of permanent magnet linear synchronous motor is wether it is out-of-step.Through analysis of characteristics of power angle of permanent magnet linear synchronous motor,the paper put forward a prevented control strategy of out-of-step of motor combining changing voltage with changing ratio of voltage and frequency,which uses double-mode fuzzy controller to achieve prevented control of out-of-step of motor.The simulation result showed that the strategy has simple arithmetic,good quality control,and so on,which can avoid out-of-step operation of permanent magnet linear synchronous motor effectively,and has higher application value.

     