QIU Shiguang, LI Siguang. A fault-tolerance topology of three-level four-leg NPC inverter[J]. Industry and Mine Automation, 2016, 42(10): 70-73. doi: 10.13272/j.issn.1671-251x.2016.10.016
Citation: QIU Shiguang, LI Siguang. A fault-tolerance topology of three-level four-leg NPC inverter[J]. Industry and Mine Automation, 2016, 42(10): 70-73. doi: 10.13272/j.issn.1671-251x.2016.10.016

A fault-tolerance topology of three-level four-leg NPC inverter

doi: 10.13272/j.issn.1671-251x.2016.10.016
  • Publish Date: 2016-10-10
  • In view of problem that it is difficult to accurately locate device failure of inverter, a fault tolerance topology of three-level four-leg NPC inverter was proposed. In the topology, short-circuit fault and open-circuit fault can be located accurately by switching device used when topology changes, so as to provide a basis for fault-tolerant control of inverter. The topology enables half-leg replacement, and can achieve fault-tolerant control of up to three inverter legs at the same time.

     